Installation quality affects seals, bearings, rod surface and machine structure. A new cylinder should move through its full stroke without being forced into alignment by pins, hoses or mounting bolts.
Verify Mechanical Alignment
Pins should enter freely; clevises should not be squeezed; spherical joints must articulate as intended. The rod should not correct a misaligned frame. External machine stops should absorb external end loads unless the design explicitly says otherwise.
Prepare Hydraulic Connections
Clean hoses and ports, confirm the thread/seal type and route hoses so they do not pull, rub or kink through complete motion.
Commission at Controlled Speed
Begin with reduced load and controlled speed where the machine procedure allows. Bleed air using the machine method, watch for stick-slip and inspect for leakage or pressure spikes.
Record a Baseline
Record normal pressure, cycle time and any position-specific motion changes. A baseline makes later diagnostics faster.

Centralina idraulica a corrente continua compatta serie EP-HPU-DC
EP-HPU-DC: unità di potenza idraulica compatta e configurabile per circuiti di cilindri alimentati a batteria o da veicoli.

Centralina idraulica a corrente alternata serie EP-HPU-AC
EP-HPU-AC: Centralina idraulica CA configurabile per sistemi di cilindri industriali fissi.

Centralina idraulica e sistema di valvole personalizzati serie EP-HPU-SYS
Il sistema di centralina idraulica e collettore valvole EP-HPU-SYS è stato progettato su misura in base al circuito del cilindro e al suo utilizzo.

Cilindro idraulico a doppio effetto metrico serie EP-KWA
Serie di cilindri a doppio effetto metrici EP-KWA con dati relativi a alesaggio, stelo, corsa, diametro esterno, lunghezza, porta e peso.
Frequently Asked Questions
Should pins need force during assembly?
No; binding is a reason to verify alignment and dimensions.
Why cycle slowly first?
It reveals interference, hose issues, trapped air or end-of-stroke problems before full load.
Can ports be identified by appearance?
Confirm thread and sealing method instead of relying on appearance.
What causes jerky motion after installation?
Air, restriction, friction, misalignment or valve behavior can contribute.
What baseline data is useful?
Pressure, cycle time, load condition and temperature where relevant.
Discuti le tue esigenze idrauliche
Inviare dettagli relativi a alesaggio, corsa, montaggio, pressione, porte, carico e utilizzo. Per le sostituzioni, includere foto e misure critiche.